Test results for KCR and DME migrating inhibitor efficiency are presented. The method of linear polarization is used in the tests on loaded reinforced concrete elements. Various durations of inhibitor activity, cracked concrete cover and different levels of reinforcement corrosion development in test parts are taken into account. The inhibitors are only partly efficient at low levels of corrosion development at an early stage, however, after two years the protective work is not verifiable. In the case of intense reinforcement corrosion a reduction in its degree is not observed, even directly after inhibitors have been applied.
Armatūros korozijos eksperimentiniai tyrimai naudojant organinės korozijos lėtiklius
Santrauka. Straipsnyje pateikti lėtiklių KCR ir DME efektyvumo eksperimentinių tyrimų rezultatai. Eksperimentiniuose tyrimuose apkrautiems betoniniams elementams taikyti tiesinės poliarizacijos metodai. Ivairios lėtiklių aktyvumo trukmės, supleišėjusio betono apsauginio sluoksnio ir skirtingų armatūros korozijos laipsnių išsivystymas eksperimentų dalyse yra įvertintas. Lėtikliai tik iš dalies veiksmingi esant žemam korozijos išsivystimo lygiui pradinėse stadijose, tačiau po dvejų metų jų apsauginis darbas nėra įrodytas. Kai yra didelė armatūros korozija, nėra nustatyta jos laipsnio sumažėjimo, netgi tuoj pat panaudojus lėtiklius.
Reikšminiai žodžiai: betonas, lėtiklis, korozija, efektyvumas, apsauga, armatūra, gelžbetonis.
First Published Online: 16 May 2013
Keyword : concrete, inhibitor, corrosion, efficiency, protection, reinforcement, reinforced concrete
This work is licensed under a Creative Commons Attribution 4.0 International License.